- Description
- Technical Data
- Equipment: Base/Base addition
- Equipment: Reservoir
- Equipment: Drive
- Equipment: Nozzles
- Equipment: Options
Airless system for intervalled application of runny liquids from a distance without the addition of air.
Main application range:
External MQL in simple, metal-cutting and chipless forming operations.
Operating principle:
The liquid flows out of the reservoir into the piston chamber. The piston is accelerated by means of a compressed air impulse and shoots the liquid at high pressure through the nozzle.
Version: P35/1-Y03-GLV-SH3 Version: P35/1- -V-SH3
Adjustability
-
Quantity of liquid (manual) at the PMC dial
-
Optional: Pressure of piston actuation air (manual)
-
Switch on/off using actuation control drive (electric, pneumatic or manual)
Term | Figure | Unit |
---|---|---|
Operating pressure | 3 - 8 | bar |
Max. dosage quantety | 0.06* for P35/1 0.12* for P35/1(4DF) | ml/h per stroke |
Lubricoolant | Lubrimax® and others | |
Recommended viscosity | 1 - 50** | mm²/s (at 40°C) |
Max. distance | 750* | mm |
Dimensions | WØxL | Unit |
---|---|---|
Base unit (without reservoir) P35/1-...-V | Ø 40 x 135 | mm |
Base unit (without reservoir) P35/1-...-GLV | Ø 40 x 270 | mm |
* maximum values refer to water as fluid
** depending on application, operating pressure, fluid and dosage quantety
(from 0.33 to 27 litres available)
Unit assembly
Wall mounted reservoirs
(electric, pneumatic or pedal-operated option)
(options)
- Stand with switchable block magnet (55x50x80) or round magnet Ø80 and with articulated bar (Lmax=250).
- Pressure reducing valve including manometer for improved regulation of spray distance and profile.